11-18
Adaptec SCSI RAID Software Reference Guide
enclosure set interval
To set the monitor reporting interval for a specific SAF-TE enclosure
management device, use the enclosure set interval
command. The monitor reporting interval indicates how often the
controller checks the status of the enclosure management device and
its associated components. In setting this value, consider the needs
of your computing environment. Setting the monitor reporting level
to less than ten seconds could cause slower system performance.
Syntax
enclosure set interval {second}
Parameters
{second}
Specifies the number of seconds for the monitor reporting
interval. You can specify 1 to n seconds where n represents the
number of seconds for the monitor reporting interval. (The
maximum value is 86,400, the number of seconds in a day.)
The default is 10 seconds.
Examples
Before setting the monitor reporting interval, you might want to use
the enclosure show status command to determine the current
monitor reporting interval setting.
As the following example shows, the current monitor reporting
interval setting is 10:
AAC0>enclosure show status
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
0 0:00:00 0 10 UNLOCKED OFF
.
.
.
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
1 0:00:00 0 10 UNLOCKED OFF