7-23
disk Commands
information. If you specify FALSE, the command does not
display detailed S.M.A.R.T. configuration information.
This switch defaults to FALSE.
/view_changeable{=boolean}
Specifies whether to display the configuration information that
can be set on a S.M.A.R.T. disk. If you specify TRUE for this
switch, the command displays the letter “X” in the column for
the configuration information that can be set. For example, an
“X” appears in the Enable Exception Control column for those
S.M.A.R.T. disks on which this value can be set.
This switch defaults to FALSE.
Examples
The following example shows how to display nondetailed
S.M.A.R.T. configuration information for all disks on the system:
AAC0>disk show smart
Executing: disk show smart
Smart Method of Enable
Capable Informational Exception Performance Error
C:ID:L Device Exceptions(MRIE) Control Enabled Count
------ ------- ---------------- --------- ----------- ----
3:00:0 N
3:01:0 N
3:02:0 N
3:03:0 N
The detailed disk show smart display contains the previous
columns of information plus the following columns:
Log Errors
Interval Timer (secs.)
Report Count
The following sections provide more information on the columns
that the disk show smart command displays.
The C:ID:L Column
The C:ID:L column displays the SCSI channel number, the SCSI
device ID, and the SCSI device logical unit number for each disk on
Vue de la page 222