11-13
enclosure Commands
The following example prepares the device in slot 0 on enclosure
management device 0 for insertion or removal as a result of using
the enclosure prepare slot command:
AAC0>enclosure prepare slot 0 0
Executing: enclosure prepare slot 0 0
You may want to use the enclosure show slot command again
to see the change in the device slot’s status, as in the following
example:
AAC0>enclosure show slot
Executing: enclosure show slot
Enclosure Slot scsiId Insert Status
--------- ---- ------ ------- ------------------------------------------
0 0 0:00:0 4 OK UNCONFIG I/R READY NOTACTIVATE
0 1 0:01:0 0 OK UNCONFIG ACTIVATE
0 2 0:10:0 0 OK UNCONFIG ACTIVATE
0 3 0:03:0 0 OK UNCONFIG ACTIVATE
0 4 0:04:0 0 OK UNCONFIG ACTIVATE
1 0 1:00:0 0 OK CONFIG ACTIVATE
1 1 1:01:0 0 OK UNCONFIG ACTIVATE
1 2 1:10:0 0 OK UNCONFIG ACTIVATE
1 3 1:03:0 0 OK UNCONFIG ACTIVATE
1 4 1:04:0 0 OK UNCONFIG ACTIVATE
Note that the Status column now displays I/R READY and
NOTACTIVATE, which means the device slot is off and ready for
the insertion or removal of a device.
Related Information
enclosure commands:
enclosure activate slot (page 11-3)
enclosure identify slot (page 11-5)
enclosure list (page 11-7)
enclosure show slot (page 11-33)