11-4
Adaptec SCSI RAID Software Reference Guide
1 3 1:03:0 0 OK UNCONFIG ACTIVATE
1 4 1:04:0 0 OK UNCONFIG ACTIVATE
The following example shows how to activate a device in slot 0 of
enclosure management device 0 using the enclosure activate slot
command:
AAC0>enclosure activate slot 0 0
Executing: enclosure activate slot 0 0
You may want to use the enclosure show slot command again
to see the change in the device slot’s status, as in the following
example. Note that the OK ACTIVATE in the status column
indicates that the device is activated and working properly.
AAC0>enclosure show slot 0
Executing: enclosure show slot 0
Enclosure Slot scsiId Insert Status
--------- ---- ------ ------- ------------------------------------------
0 0 0:00:0 4 OK UNCONFIG ACTIVATE
0 1 0:01:0 0 OK UNCONFIG ACTIVATE
0 2 0:10:0 0 OK UNCONFIG ACTIVATE
0 3 0:03:0 0 OK UNCONFIG ACTIVATE
0 4 0:04:0 0 OK UNCONFIG ACTIVATE
1 0 1:00:0 0 OK CONFIG ACTIVATE
1 1 1:01:0 0 OK UNCONFIG ACTIVATE
1 2 1:10:0 0 OK UNCONFIG ACTIVATE
1 3 1:03:0 0 OK UNCONFIG ACTIVATE
1 4 1:04:0 0 OK UNCONFIG ACTIVATE
Related Information
enclosure commands:
■ enclosure identify slot (page 11-5)
■ enclosure list (page 11-7)
■ enclosure prepare slot (page 11-12)
■ enclosure show slot (page 11-33)