ASI Hardware Installation Guide
8
Copyright2000, Advertising Specialty Institute. All Rights Reserved. HRDW200001.doc Rev. 5/16/00
Modifying the Jumpers on the Adaptec 1505 Card
Below is a picture of the Adaptec 1505 SCSI Host Adapter. The white arrow points to the area
of the card where the JUMPERS are located.
The arrow above points to the area on the card where the jumpers are located. The jumper
area is magnified below:
You need to change the jumpers on the card to match the settings that you wrote down earlier.
The following section shows you how to do this.
Changing the I/O Address of the 1505 Card
In order to change the I/O Address, you must start by modifying the I/O Address. The I/O
address jumper is the top-most set of pins, labeled ALT. The default position for the jumper is
OFF. (The term “OFF” means that the black plastic jumper is only mounted on one pin.)
When the top jumper is OFF, the I/O address is 340.