2-24
Storage Manager on ROM
RAID 0 arrays are comprised of any number of drives greater than 1.
RAID 1 arrays are comprised of multiple pairs of drives. RAID 5
arrays contain three or more drives.
After you create the arrays, one or more arrays of the same RAID
level can be combined into a multilevel RAID (see Creating a
Multilevel RAID on page 2-28). Arrays are striped into multilevel
RAIDs by the controller firmware. All the drives in an array or
multilevel RAID must be attached to the same controller, and appear
to the host as a single Logical Storage Unit (LSU).
Note: Arrays do not start building until a Set System Config
action has been performed.
The Array Information tab displays general array information and
hardware configuration. It is divided into either two or three parts:
Description, SCSI Capabilities (for SCSI based RAID controllers
only), and Status.
The Description section displays a general description of the
highlighted array, as follows:
Description RAID level used for the array.
Revision Firmware revision of the RAID controller.
Address RAID address in the form
dDbBtTdD, as described in
Device Address Syntax on page 4-2. Display contains as
much information as necessary to unambiguously
define the address of the device. Controllers always are
assigned the lowest logical address of any device in the
array.
Capacity The usable capacity of the array in MB. The available
capacity depends upon the RAID level of that array.
Removable
Read Only
As reported by the devices in the array.
Block Size The sector (block) size of the selected device in bytes.
For hard drives, the value should be 512. SCSI only—If
the size is not 512, use SMOR to do a low-level format
and create 512-byte sectors. See Formatting a Drive –
SCSI only on page 2-31 for more information.
Stripe Size Displays the stripe size used to create the RAID.