11
SCSI Card 2906
Connecting External SCSI Devices
1
Be sure that each external SCSI device you are installing has a
unique SCSI ID from 0 to 6. Refer to the SCSI device’s docu-
mentation to determine the SCSI ID setting.
If any two SCSI devices (external or internal) you are connect-
ing to the SCSI Card 2906 have the same SCSI ID, change the
SCSI ID on one SCSI device. The SCSI Card 2906 is preset to
SCSI ID 7 and should not be changed.
For most external SCSI devices, the SCSI ID is set with a switch
on the back of the SCSI device as shown below. See the SCSI
Card 2906 Users Reference for additional information on SCSI
IDs.
2
Connect one end of the external SCSI cable to the SCSI Card
2906 external SCSI connector as shown in the following dia-
gram. Secure the cable to the connector on the SCSI Card 2906
by tightening the thumb screws on the cable connector.
SCSI ID Switch