Appendix H: Technical Specifications 130
Environmental Specifications
Note: Adaptec RAID controllers require adequate airflow to operate reliably. The recommended
airflow is 200 LFM. Forced airflow is recommended.
Note: Ambient temperature measured 1” from RAID processor.
DC Power Requirements
Current Requirements
Ambient temperature with forced airflow 0 °C to 55 °
C
Ambient temperature without forced airflow 0 °C to 40 °
C
Ambient temperature with Battery Backup Unit
(BBU)
0 °C to 40 °
C
Relative humidity 10% to 90%, noncondensing
Altitude Up to 3,000 meters
Bus Type Description Requirements
PCIe Ripple and noise 50 mV peak-to-peak (max)
PCIe DC Voltage 3.3 V ± 9%, 12 V ± 8%
Adaptec Model Typical Current
Adaptec RAID 5085 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5805/5805Q 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5405 0.45A @ 3.3VDC; 0.94A @ 12.0VDC
Adaptec RAID 5445 0.45A @ 3.3VDC; 1.0A @ 12.0VDC
Adaptec RAID 5805Z/5805ZQ 0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC
Adaptec RAID 5405Z 0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC
Adaptec RAID 5445Z 0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC
Adaptec RAID 51245 0.47A @ 3.3VDC; 1.68A @ 12.0VDC
Adaptec RAID 51645 0.47A @ 3.3VDC; 1.72A @ 12.0VDC
Adaptec RAID 52445 0.47A @ 3.3VDC; 1.78A @ 12.0VDC
Adaptec RAID 2045 0.43A @ 3.3VDC; 0.83A @ 12.0VDC
Adaptec RAID 2405/2405Q 0.43A @ 3.3VDC; 0.83A @ 12.0VDC
Vue de la page 129

Commentaires sur ces manuels

Pas de commentaire