Adaptec 5405Z Guide de l'utilisateur Page 102

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 136
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 101
Appendix D: Using the Array Configuration Utility for DOS 102
Sample Scripts
This command invokes the ACU and creates arrays on controller 1 based on the array
keywords defined in the script file A:\RAID.ACU. It also configures Channel 0 and saves a log
of the operation in the log file C:\RAID.LOG:
A:\> ACU /P A:\RAID.ACU /L C:\RAID.LOG /C1
This sample script file is the RAID.ACU script as referred to in the ACU command above. This
script creates these arrays—a 500 MB single-disk volume, and a 2-GB two-disk drive RAID 1
with a hot spare:
# Create a 500MB volume labeled ‘MySystem’
Array=MySystem
Type=Volume
Size=500MB
Drives=0:0:0
End
# Create a 2GB mirror labeled ‘MyMirror’
Array=MyMirror
Type=RAID1
Size=2GB
5 Unable to read system configuration—The ACU was unable to get the configuration
information from the specified controller.
6 No drives detected.
7 Specified drive not found in system.
8 Specified array size too small—You specified an array size that is smaller than the
minimum size allowed for this array.
9 Specified array size too big—You specified an array size that is larger than the maximum
size allowed for this array.
10 Number of drives do not match the array type—The number of drives you selected is
invalid for the type of array specified.
11 Unable to initialize drive.
12 Error occurred while creating array.
13 Too many spare drives assigned—You attempted to assign more than the maximum
number of hot spares allowed for the specified array.
14 Insufficient memory to run the application.
15 Incorrect controller number.
16 Controller not responding.
17 Build/Verify/Clear failed.
18 Cannot use drives on shared channel.
21 Failed in getting kernel version. Unknown product ID.
22 Kernel timeout in writing command.
23 No RAID channels available
24 Error: wrong stripe size in creating array - script mode.
100 You ran ACU and made changes—The ACU exited with no errors (success) and you must
restart the computer.
Code Description
Vue de la page 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 135 136

Commentaires sur ces manuels