Adaptec SATA AND SCSI RAID CONTROLLERS Manuel d'utilisateur Page 115

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 165
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 114
D-12
Command Line Interface
Disk Show Defects
The
disk show defects
command shows the following types on
information:
Total number and location of primary defects (defects that
originate during manufacturing)
Total number and location of grown defects (defects that
originate after manufacturing)
Example
In the example below, the drive contains five primary defects and
no grown defects:
AAC0> disk show defects /full=true (0,1,0)
Executing: disk show defects /full=TRUE (CHANNEL=0,ID=1,LUN=0)
Number of PRIMARY defects on drive: 5
Defect 1 at cylinder 229, head 7, sector 203
Defect 2 at cylinder 575, head 0, sector 219
Defect 3 at cylinder 576, head 0, sector 55
Defect 4 at cylinder 578, head 0, sector 238
Defect 5 at cylinder 579, head 0, sector 74
Number of GROWN defects on drive: 0
Disk Verify
The
disk verify
command shows the following types on
information:
Total number and location of primary defects (defects that
originate during manufacturing)
Total number and location of grown defects (defects that
originate after manufacturing)
Displaying Array Information
The CLI allows you to display and manage array attributes using
the following commands:
Container List
Container Show Cache
Container List
The
container list
attributes are defined as follows:
Drive Letter
Letter associated with an array. Not
automatically assigned when you create an array.
Vue de la page 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 164 165

Commentaires sur ces manuels

Pas de commentaire