Chapter 15: Managing Controllers and Disk Drives 144
7 Review the update summary, then click Apply.
8 When prompted, click Yes to begin the update.
Caution: Do not power down the controller(s) during the
update.
9 When the update is complete, click OK. Then, restart the server(s) to
activate the new firmware images.
Setting a Disk Drive to ‘Failed’
Before you can remove a disk drive from a server, you must set it to a
failed state to protect your data.
Caution: You may lose data or damage your disk drive if you
remove a disk drive without first setting it to a failed state.
You can set a disk drive to a failed state if:
The disk drive is not part of a logical drive, or
The disk drive is part of a redundant, healthy logical drive
You can’t set a disk drive to a failed state if doing so will take a logical
drive offline.
To set a disk drive to a failed state:
1 In the Physical Devices View, click the disk drive.
2 In the menu bar, select Actions, then click Set drive state to failed.
3 Click Ye s to set the drive status to failed.
4 Remove and replace the disk drive.
5 If the logical drive that the disk drive belongs to is failed, see
Recovering from a Disk Drive Failure on page 147.