Adaptec SAS RAID Controllers Guide d'installation Page 75

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 148
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 74
Appendix B HBA Specifications 61
Physical layer: Consists of two sets of differential lines, one receive set and one
transmit set [4-wire total]. This layer defines the cable, connector, and transceiver
[Transmitter / Receiver] characteristics.
PHY layer: Connects the differential Transmitter and Receiver circuits [ICs] to the
Physical Layer.
Link layer
Port layer
Application layer
The external connector accepts 4 physical links and the cable may hold between 1
and 4 physical links. Internal connectors are defined and two data rates are defined:
1.5 Gbps and 3.0 Gbps over a 100 ohm [+ 15 ohm] differential impedance cable.
SAS uses the Serial ATA physical interface, including the connector receptacle and
connector plugs. SAS transmits data using 8B/10B at a maximum level of 1.2 volts
[Tx voltage = 800-1600mV], [Rx voltage = 275-1600mV]. SAS uses big-endian, while
SATA uses little-endian byte ordering. SAS uses a 32 bit CRC. SAS uses LVDS.
Connector Pin Definitions
SAS Pin-Out
Two types of ports are defined: A Narrow Port communicates over a narrow link and
contains only one transmit/receive pair, and a Wide Port communicates over a wide
link and contains more than one transmit/receive pair. The ports reside in the PHY
layer, and the link resides in the physical layer.
TABLE B-2 SAS Pin-Out
Signal Name 1 Physical Link 2 Physical Links 3 Physical Links 4 Physical Links
Rx 0+ S1 S1 S1 S1
Rx 0- S2 S2 S2 S2
Rx 1+ N/A S3 S3 S3
Rx 1- N/A S4 S4 S4
Rx 2+ N/A N/A S5 S5
Rx 2- N/A N/A S6 S6
Vue de la page 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 147 148