Introduction
The Ctr and State Items
The Ctr item displays the ID number of the array associated with
the task. In the example, the array’s ID is 0 (zero).
The State item displays the state of the task along with a running
percentage value that indicates the progress of the currently
running task. The item shows the percentage in tenths of a percent
increments. The currently running task is complete when the State
item displays 100%.
MMR Merge a broken mirror task.
The array merge command causes the MMR value to
display.
MSC array scrub task. The array scrub command causes the
MSC value to display.
NTF array format task with an NTFS file system specified. The
array format command with the /file_system switch
set to NTFS causes the NTF value to display.
R5R RAID-5 rebuild task.
R5S RAID 5 array create task with the scrub method specified. The
array create raid5 command with the /scrub switch
specified causes the R5S value to display.
RCF array reconfigure task. The array reconfigure command
causes the RCF value to display.
SCV Verify all blocks on a SCSI disk device task. The disk
verify command causes the SCV value to display.
SCZ Clear an entire SCSI disk task. The disk zero command
causes the SCZ value to display.
SVR Verify all blocks and repair bad blocks on a SCSI disk device
task. The disk verify command with the /repair switch
causes the SVR value to display.
Table 1-7 Function Values (Continued)