16
Adaptec Fibre Card 9110G Users Reference
seconds to avoid NT timeouts (Event ID 9s on Windows NTs
System EventLog).
To increase the timeout value:
a Goto the Start button and select Run…
b For Windows NT 4, type:
a:\winnt4\timeout.reg
For Windows 2000, type:
a:\win2000\timeout.reg
c Select OK for the pop up window.
d You need to reboot in order for the registry setting to take
place.
2 N_port support:
If the switch is configured as an F_port, the adapter should be
configured as an N_port. When the adapter is configured as an
N_port, only one of the two connectors can be used (internal
HSSDC connector or the GBIC module).
To enable or disable N_Port:
a Goto the Start button and select Run…
b For Windows NT 4, type:
a:\winnt4\nport_on.reg
For Windows 2000, type:
a:\win2000\nport_on.reg
Replace nport_on.reg with nport_off.reg if you
would like to disable N_port support.
c Select OK for the pop up window.
d You need to reboot in order for the registry setting to take
place.