4 Login to the old master target using iSCSI GUI.
If required reset the authentication.
logical manage auth none
5 Activate the volume and assign drive letter via Disk Manager.
Completing Stalled Replica Update
When you are updating a replica the replication might get stalled due to non-
availability of the destination site.
To complete the replica update:
1 Check the availability of the destination site.
2 Verify the network connectivity between the source and destination sites.
3 Abort the stalled replica update set so that it is changed to Replicated LUF state.
4 Reschedule the replica update job.
Unable to Perform Replication When Source and Destination have Static
IP Address
When the source and destination sites are in the same network and are assigned
with a static IP address in Ethernet port1, the replication will happen. If the IP
address of the destination site is changed and set to the private network the
replication will not happen. Ensure that for the replication to happen successfully,
make sure the iscsi connection of the iSCSI storage appliance have the same IP
address and are in the same network.