A Reference Guide for Optimizing Dell™ SCSI Solutions
Authored By:
Dell SCSI Storage Solution Team
November 17, 2005 rev A02
____________________
Information in this document is subject to change without notice.
© Copyright 2005 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly
forbidden.
THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN
TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS
PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND.
Dell, the Dell Logo, PowerVault, PowerEdge and OpenManage are trademarks of Dell Inc.
Microsoft is a registered trademark of Microsoft Corporation. Other trademarks and trade names
may be used in this document to refer to either the entities claiming the marks and names or their
products. Dell disclaims proprietary interest in the marks and names of others.
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1

; A Reference Guide for Optimizing Dell™ SCSI Solutions Authored By: Dell SCSI Storage Solution Team November 17, 2005 r

Page 2 - PAGE 2 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 10 11/17/2005 • RAID 50 – Recommended for those solutions that require a balan

Page 3 - 1. Introduction

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 11 11/17/2005 • RAID 1 – Possible solution in situations which do not require

Page 4 - PAGE 4 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 12 11/17/2005 that can afford some downtime and rely on backups to restore data

Page 5 - PAGE 5 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 13 11/17/2005 Additional configuration factors Hot Spares Hot Spare functionali

Page 6 - PAGE 6 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 14 11/17/2005 3. Dell’s Product Offering PowerVault™ 220S & 221S Storage

Page 7 - PAGE 7 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 15 11/17/2005 (SCSI) host adapter with RAID control capabilities. It provides r

Page 8 - PAGE 8 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 16 11/17/2005 • Table 3-2: PERCs and Cable Type PV22xS Controller/Cable Matrix

Page 9 - PAGE 9 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 17 11/17/2005 In addition, many Dell servers & storage solutions offer cros

Page 10 - PAGE 10 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 18 11/17/2005 • Table 3-4: PERC 2 & PERC 3 Support Matrix (4G & 5G ser

Page 11 - PAGE 11 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 19 11/17/2005 4. PV22xS Enclosure Overview The PV22xS SCSI Enclosure provides

Page 12 - PAGE 12 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 2 11/17/2005 TABLE OF CONTENTS A REFERENCE GUIDE FOR OPTIMIZING DELL SCSI SOLUT

Page 13 - PAGE 13 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 20 11/17/2005 The primary EMM must always be present. Regardless of whether SE

Page 14 - Performance

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 21 11/17/2005 Figure 4-3 Split Bus Cabling Options to a

Page 15 - PAGE 15 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 22 11/17/2005 a failover condition, access rights to the disk array assigned to

Page 16 - Wide HD to Wide HD on PE2600

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 23 11/17/2005 be reserved for use by the second SCSI controller. A mapping of

Page 17 - SCSI Solutions:

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 24 11/17/2005 modules is not supported. For more details, refer to section 5 (

Page 18 - PowerVault Enclosure Support

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 25 11/17/2005 properly quiescent before the remove/replacement operation takes

Page 19 - PAGE 19 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 26 11/17/2005 Cable Connector Controller Connector P-type connector – Male P-t

Page 20 - PAGE 20 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 27 11/17/2005 • Table 4-2: PV22xS Configuration Topologies Vs RAID Level Perfo

Page 21 - PAGE 21 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 28 11/17/2005 PV22xS consists of four digital temperature probes, which in conj

Page 22 - PAGE 22 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 29 11/17/2005 5. SCSI Host Bus Adapters / SCSI RAID This section addresses co

Page 23 - PAGE 23 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 3 11/17/2005 A Reference Guide for Optimizing Dell SCSI Solutions 1. Introduc

Page 24 - PAGE 24 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 30 11/17/2005 Controller Family Aside from the technical, physical and feature

Page 25 - PAGE 25 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 31 11/17/2005 In contrast, Adaptec controllers will only use space on all ‘chil

Page 26 - PAGE 26 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 32 11/17/2005 back up unit (see Table 5-2), there is a risk of data loss if sy

Page 27 - PAGE 27 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 33 11/17/2005 For more details on rebuild process please refer to Appendix A –

Page 28 - PAGE 28 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 34 11/17/2005 drives supported by the PV22xS). Mixing spindle speeds within the

Page 29 - PAGE 29 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 35 11/17/2005 • Table 5-1: Pros and Cons for Spanning Arrays with various RAID

Page 30 - PAGE 30 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 36 11/17/2005 Table 5-2 – Controller Families & Features: Part 1 PERC 4e

Page 31 - PAGE 31 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 37 11/17/2005 Table 5-2 – Controller Families and Features: Part 2 PERC 4/SC

Page 32 - PAGE 32 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 38 11/17/2005 Table 5-2 – Controller Families and Features: Part 3 PERC 3/DC

Page 33 - PAGE 33 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 39 11/17/2005 6. Summary and Conclusions After analyzing and assessing the imp

Page 34 - PAGE 34 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 4 11/17/2005 Understanding each of the storage components with respect to these

Page 35 - PAGE 35 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 40 11/17/2005 • Table 6-1: Typical Storage Recommendation for Different Storag

Page 36 - PAGE 36 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 41 11/17/2005 7. Appendix – A: References 1. ANSI T10/1365D SCSI Parallel In

Page 37 - LSI 53C1020 LSI 53C1030

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 42 11/17/2005 8. Appendix – B: Glossary Array – Collection of multiple physic

Page 38 - PAGE 38 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 43 11/17/2005 9. Appendix – C: About the Dell SCSI Storage Solution Team Autho

Page 39 - 6. Summary and Conclusions

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 44 11/17/2005 10. Appendix – D: Revision History Revision Description Date M

Page 40 - PAGE 40 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 5 11/17/2005 the server/storage solution and will determine what RAID configura

Page 41 - 7. Appendix – A: References

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 6 11/17/2005 RAID 5 RAID 5 has good I/O performance, data protection and relati

Page 42 - 8. Appendix – B: Glossary

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 7 11/17/2005 • RAID 10 – Recommended for enterprise mission critical e-mail se

Page 43 - PAGE 43 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 8 11/17/2005 • RAID 5 – Recommended for databases that require maximum storage

Page 44 - PAGE 44 11/17/2005

A REFERENCE GUIDE FOR OPTIMIZING DELL™ SCSI SOLUTIONS VER A02 PAGE 9 11/17/2005 • RAID 5 – Recommended for web servers that require maximum stora