Chapter 5: Installing the Controller and Disk Drives 39
Monitoring Disk Drives with ICP Storage Manager
ICP Storage Manager allows you to monitor the status of your SAS, SATA, or SCSI disk drives.
Within ICP Storage Manager, you can select a disk drive object and a command will be sent to
the backplane (for internal disk drives) or enclosure (for external disk drives). The LED
associated with that disk drive will flash. The following table describes the LED flash states. For
more information refer to the ICP Storage Manager Help.
Controller Device State Slot State LED Flash State
Failed Device is faulty On
Rebuilding Device is rebuilding Slow flash
Blink Identify the device Fast flash
Other No error Off