DPU4E Maintenance Utilities
If prompted to setup the programming hardware then choose
ByteBlaster as the type and LPT1 as the port.
If prompted, click the “Detect JTAG Chain Info” button to verify
that the DPU and PC are properly connected.
As the programming and verification steps occur, their progress
will be shown in bar chart form near the top of the programming
window.
If the programming process completes without errors, run the
verify step again to make sure the flash was successful (press the
“Verify” button).
If errors are reported then try to program again, followed by
another Verify.
WARNING – If there are errors during programming, try again right
away. If you still get errors, immediately turn off the DPU. Do NOT
let a DPU with an improperly or incompletely programmed CPLD sit
with power on. It is possible to cause hardware damage to the DPU
in this condition. Verify your connections and shorten the PC to
ByteBlaster extension cable and try again. Try inserting a CPLD
Programming Adapter (Metso Automation #181549) between the
DPU’s JTAG connector and the ByteBlaster. NEVER put an
extension cable between the DPU and the B
teBlaster.
If the CPLD was programmed correctly, remove the DPU from
the chassis and remove the ByteBlaster cable from the DPU.
Remove the ribbon cable connector from the BDM connector on
the DPU.
Insert the DPU back into the chassis.
Make sure the mode switch is set to “F”, place the keyswitch in
the proper position and verify that the DPU boots properly and
goes on-line.
Metso Automation • 278590 •